READY2RUN: DRILLING BLANKS

2 HOLE 30° HELIX, 3x, 5x, 7xD, GROUND h6, 6mm - 25mm DIA, CUT TO LENGTH, with 120° POINT & CHAMFERED COOLANT SLOT

...

Browse By Product Groups

Showing: 1-29
Sort by
California Proposition 65 Warning
EDP # Details Diameter OAL
Ground Series   Order Code mm inch mm inch
9079150060024
7915   006.002
6.00mm x 63.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 1.50 mm; d 0.6 mm; Pitch 20.40 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 6 0.2362 63 2.4803
9079160060004
7916   006.000
6.00 mm x 83.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; chip groove on one end B 1.00 mm T 1.20 mm; DK460UF/GC100S (10% Co) 6 0.2362 83 3.2677
9079160060014
7916   006.001
6.00 mm x 75.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120 degree point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 6 0.2362 75 2.9528
9079150060004
7915   006.000
6.00mm x 67.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.7 mm; Pitch 32.65 mm; 120º point on one end; chip groove on one end B 1.0 mm T 1.2 mm; DK460UF/GC100S (10% Co) 6 0.2362 67 2.6378
9079150060014
7915   006.001
6.00mm x 67.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.8 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 6 0.2362 67 2.6378
9073490060004
7349   006.000
6.00 mm x 98.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.70 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 6 0.2362 98 3.8583
9073490060024
7349   006.002
6.00 mm x 76.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.80 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 6 0.2362 76 2.9921
9079150080004
7915   008.000
8.00mm x 80.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 8 0.3150 80.5 3.1693
9079160080004
7916   008.000
8.00 mm x 92.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 8 0.3150 92.5 3.6417
9073490080004
7349   008.000
8.00 mm x 107.50 mm OAL; 2 Coolant Ducts; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 8 0.3150 107.5 4.2323
9073490080014
7349   008.001
8.00 mm x 117.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 8 0.3150 117.5 4.6260
9079150100004
7915   010.000
10.00mm x 90.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.4 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 10 0.3937 90.5 3.5630
9079160100004
7916   010.000
10.00 mm x 104.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 10 0.3937 104.5 4.1142
9073490100004
7349   010.000
10.00 mm x 132.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.40 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 10 0.3937 132.5 5.2165
9079150120004
7915   012.000
12.00mm x 104.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 12 0.4724 104 4.0945
9079160120004
7916   012.000
12.00 mm x 120.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 12 0.4724 120 4.7244
9073490120004
7349   012.000
12.00 mm x 157.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 12 0.4724 157 6.1811
9079150140004
7915   014.000
14.00mm x 109.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 14 0.5512 109 4.2913
9079160140004
7916   014.000
14.00 mm x 126.0 mm OAL; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 14 0.5512 126 4.9606
9073490140004
7349   014.000
14.00 mm x 184.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 14 0.5512 184 7.2441
9079150160004
7915   016.000
16.00mm x 117.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S(10% Co) 16 0.6299 117.5 4.6260
9079160160004
7916   016.000
16.00 mm x 135.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 16 0.6299 135.5 5.3346
9073490160004
7349   016.000
16.00 mm x 206.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 16 0.6299 206.5 8.1299
9079150180004
7915   018.000
18.00mm x 125.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 18 0.7087 125.5 4.9409
9079160180004
7916   018.000
18.00 mm x 145.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 18 0.7087 145.5 5.7283
9073490180004
7349   018.000
18.00 mm x 225.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 18 0.7087 225.5 8.8780
9079150200004
7915   020.000
20.00mm x 134.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 20 0.7874 134 5.2756
9079160200004
7916   020.000
20.00 mm x 156.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 20 0.7874 156 6.1417
9073490200004
7349   020.000
20.00 mm x 247.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End DK460UF/GC100S (10% Co) 20 0.7874 247 9.7244