READY2RUN: DRILLING 3XD

3xD, GROUND h6, 6mm - 25mm DIA, CUT TO LENGTH, with 120° POINT & CHAMFERED COOLANT SLOT

...
Showing: 1-10
Sort by
California Proposition 65 Warning
EDP # Details Diameter OAL
Ground Series   Order Code mm inch mm inch
9079150060024
7915   006.002
6.00mm x 63.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 1.50 mm; d 0.6 mm; Pitch 20.40 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 6 0.2362 63 2.4803
9079150060004
7915   006.000
6.00mm x 67.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.60 mm; d 0.7 mm; Pitch 32.65 mm; 120º point on one end; chip groove on one end B 1.0 mm T 1.2 mm; DK460UF/GC100S (10% Co) 6 0.2362 67 2.6378
9079150060014
7915   006.001
6.00mm x 67.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 2.00 mm; d 0.8 mm; Pitch 32.65 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 6 0.2362 67 2.6378
9079150080004
7915   008.000
8.00mm x 80.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 3.60 mm; d 1.25 mm; Pitch 43.53 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 8 0.3150 80.5 3.1693
9079150100004
7915   010.000
10.00mm x 90.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 4.80 mm; d 1.4 mm; Pitch 54.41 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 10 0.3937 90.5 3.5630
9079150120004
7915   012.000
12.00mm x 104.0 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.25 mm; d 1.55 mm; Pitch 65.30 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 12 0.4724 104 4.0945
9079150140004
7915   014.000
14.00mm x 109.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 6.70 mm; d 1.90 mm; Pitch 76.18 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 14 0.5512 109 4.2913
9079150160004
7915   016.000
16.00mm x 117.5 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 8.00 mm; d 2.10 mm; Pitch 87.06 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S(10% Co) 16 0.6299 117.5 4.6260
9079150180004
7915   018.000
18.00mm x 125.50 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 9.00 mm; d 2.30 mm; Pitch 97.95 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 18 0.7087 125.5 4.9409
9079150200004
7915   020.000
20.00mm x 134.00 mm OAL; 2 Coolant Ducts 30º Helix; Ground to h6 Tol; BC 10.00 mm; d 2.50 mm; Pitch 108.83 mm; 120º point on one end; Chamfered and Slotted on Back End Ground h6 DK460UF/GC100S (10% Co) 20 0.7874 134 5.2756